Chloridos Mini - Lite Analyser Upgrade
The ChloriDos™ Upgrade allows your existing ChloriDos™ Mini / Lite system to monitor accurately the residual Chlorine Dioxide in the controlled process.
The Upgrade offers a unique ‘boost’ feature to maintain disinfection levels during low flow periods so maintaining residual Chlorine Dioxide levels in the process. It can also suspend dosage at high residual levels as a further safety feature.
The upgrade Analyser can be utilised alongside the ChloriDos™ Batch Unit to control process pumps and monitor an individual process
Chlorine Dioxide generation, dosing and monitoring
General Technical Data
- Conex Dia 1 analyser/controller
- Aquacell with hydro mechanical cleaning
- Measuring range 0-10 mg/l ClO2
- Analogue or digital water meter inputs
- Water meter overdose protection
- Unique Boost feature to maintain disinfection levels during low flow periods
- Safety flow sensor in sample flow
- Volt free outputs for connection to BMS systems
- Sample cell max operating pressure 3 Bar
- Remote alarm terminals
- 4-20mA scalable analogue outputs for ClO2 and temperature
- Superior build quality for trouble free operation
All ChloriDos™ Analysers are supplied fully wet/pressure tested to 3 Bar with fully configured control software, completed operational diagnostic checks, unique ID serial numbers and full documentation.
|
ChloriDos™ Model |
Product Description |
|
CDS-UPGRADE |
Conex Dia 1 compact (c/w connections for ChloriDos™) |
Conex Technical Data
|
Mains supply |
230V ±10% 50Hz 30mA RCBO protection recommended (6A) |
|
Electronics |
16 bit microprocessor system |
|
Display |
High resolution plain text LCD with back light |
|
Relay Outputs |
1 alarm relay 2 controller relays (230V ,6A, max 550VA) |
|
Signal Outputs |
4 analogue (4-20mA) outputs galvanically isolated from the inputs, max load 500 Ohm |
Proportional Band (Xp) |
0.1 to 3000% |
|
Temperature compensation |
Manually or automatically from temperature sensor (fitted) |
Reset time (Tn) |
1 to 3000s resolution 1s |
|
Calibration |
With plausibility check |
Deriv action time (Tv) |
1 to 3000s resolution 1s |
|
Admissable temperature |
Operation: 0 to 50⁰C Storage: -22 to 65⁰C |
On time |
0.1 to 10s |
|
Relative Air Humidity |
Max 90% at 40⁰C (not condensing) |
Constant load |
0 to 50% |
|
Limit Values |
Adjustable to physical variable within measuring range |
Environmental protection level |
IP65 |
|
Hysteresis |
0 to 50% of the upper limit of the measuring range |
Back board dimensions |
495 x 495 mm |
|
Set Point selection |
0 to 100% of measuring range |
Weight |
5 kg |
|
Signal Outputs |
4 analogue (4-20mA) outputs galvanically isolated from the inputs, max load 500 Ohm |
Proportional Band (Xp) |
0.1 to 3000% |
|
Temperature compensation |
Manually or automatically from temperature sensor (fitted) |
Reset time (Tn) |
1 to 3000s resolution 1s |
|
Calibration |
With plausibility check |
Deriv action time (Tv) |
1 to 3000s resolution 1s |
|
Admissable temperature |
Operation: 0 to 50⁰C Storage: -22 to 65⁰C |
On time |
0.1 to 10s |
|
Relative Air Humidity |
Max 90% at 40⁰C (not condensing) |
Constant load |
0 to 50% |
|
Limit Values |
Adjustable to physical variable within measuring range |
Environmental protection level |
IP65 |
|
Hysteresis |
0 to 50% of the upper limit of the measuring range |
Back board dimensions |
495 x 495 mm |
|
Set Point selection |
0 to 100% of measuring range |
Weight |
5 kg |
Analyser Upgrade Package Contents
- Conex Dia 1 compact
- Pressure loading valve kit
- Wall mounting kit
- 6/12 sample line
- Sample isolator valve assembly
- Jaco fittings for sample line
- Full installation instruction including wiring instructions for connection to ChloriDos™ Lite or Mini
- Full installation instructions for connection to ChloriDos™ Batch Unit
Optional extras
- 10” sample line filter bowl kit
- 10” 20 micron washable filter
- Spin down sediment trap 3/4” uPVC filter assembly 104 micron
- Tmac remote monitoring system
Sample cell with measuring electrode and reference probe